What the Baltimore sign code and sign ordinance allow, summarised from Baltimore City Code, Title 17 — Signs. Every figure below shows the ordinance's own wording, so you can check it rather than take our word for it.
Wall sign — maximum area
Table 17-201C-2: Ground floor wall sign 30 sq. ft. (1 per tenant w/ direct ground-floor access); Above ground floor 2 sq. ft. per linear foot of building frontage
| Sign Types by Zoning District * | Zoning District Requirements | Area of Special Signage Control (ASSC) | |||||
|---|---|---|---|---|---|---|---|
| Approval Method | Maximum Area Per Sign | Height, Width, & Location Req'ts | Maximum Quantity | Sign Types Allowable for ASSC Deviation | Maximum Percentage Deviation for Height, Width, & Area | Quantity Deviation | |
| R-1A through R-4 | |||||||
| Electronic Sign (Category I) | CB | 15 sq. ft. | Per Sign Type Used | 1 per lot | Not Eligible | ||
| Freestanding (Monument) | A | 32 sq. ft. | Max. Hgt. 6 ft. | 1 per lot | Not Eligible | ||
| Painted / Mural Sign | CB | 36 sq. ft. | 1 per lot | Not Eligible | |||
| Provisional Fence Sign | A | Max. Hgt. 12 ft. | Not Eligible | ||||
| Wall Sign (Ground Floor & Above Ground Floor) | A | 18 sq. ft. | 1 per lot | Not Eligible | |||
| R-5 through R-7 | |||||||
| A-Frame | A | 8 sq. ft. per side | Max. Hgt. 4 ft. | 1 per lot | Not Eligible | ||
| Awning or Canopy Sign & Open-Structural Framework Sign | A | 2 sq. ft. per linear foot of awning, canopy, or frame width | 1 per lot | Not Eligible | |||
| Banner Sign (Projecting) | A | 12 sq. ft. | 2 per lot | Not Eligible | |||
| Electronic Sign (Category I) | CB | 15 sq. ft. | Per Sign Type Used | 1 per lot | Not Eligible | ||
| Freestanding (Monument) | A | 32 sq. ft. | Max. Hgt.6 ft. | 1 per lot | Not Eligible | ||
| Painted / Mural Sign | CB | 36 sq. ft. | 1 per lot | Not Eligible | |||
| Provisional Fence Sign | A | Max. Hgt. 12 ft. | Not Eligible | ||||
| Wall Sign (Ground Floor & Above Ground Floor) | A | 18 sq. ft. | 1 per lot | Not Eligible | |||
| R-8 through R-10 | |||||||
| A-Frame | A | 8 sq. ft. per side | Max. Hgt. 4 ft. | 1 per lot | Not Eligible | ||
| Awning or Canopy Sign & Open-Structural Framework Sign | A | 2 sq. ft. per linear foot of awning, canopy, or frame width | 1 per lot | Not Eligible | |||
| Banner Sign (Projecting) | A | 18 sq. ft. | 2 per lot | Not Eligible | |||
| Electronic Sign (Category I) | CB | 15 sq. ft. | Per Sign Type Used | 1 per lot | Not Eligible | ||
| Freestanding (Monument) | A | 32 sq. ft. | Max. Hgt. 6 ft. | 1 per lot | Not Eligible | ||
| Painted / Mural Sign | CB | 36 sq. ft. | 1 per lot | Not Eligible | |||
| Projecting Sign (Above Ground Floor) | A | 12 sq. ft. | 1 per lot | Not Eligible | |||
| Provisional Fence Sign | A | Max. Hgt. 12 ft. | Not Eligible | ||||
| Wall Sign (Ground Floor & Above Ground Floor) | A | 36 sq. ft. | 1 per interior lot, 2 per corner lot | Not Eligible | |||
| R-MU | |||||||
| A-Frame | A | 8 sq. ft. per side | Max. Hgt. 4 ft. | 1 per lot | Not Eligible | ||
| Electronic Sign (Category I) | CB | 15 sq. ft. | Per Sign Type Used | 1 per lot | Not Eligible | ||
| Freestanding (Monument) | A | 32 sq. ft. | Max. Hgt. 6 ft. | 1 per lot | Not Eligible | ||
| Painted / Mural Sign | CB | 16 sq. ft. | 1 per lot | Not Eligible | |||
| Projecting Sign (Ground Floor & Above Ground Floor) | A | 4 sq. ft. | 1 per lot | Not Eligible | |||
| Provisional Fence Sign | A | Max. Hgt. 12 ft. | Not Eligible | ||||
| Wall Sign (Ground Floor & Above Ground Floor) | A | 18 sq. ft. | 1 per lot | Not Eligible | |||
| D-MU | |||||||
| A-Frame | A | 8 sq. ft. per side | Max. Hgt. 4 ft. | 1 per lot | Not Eligible | ||
| Freestanding (Monument) | A | 32 sq. ft. | Max. Hgt. 6 ft. | 1 per lot | Not Eligible | ||
| Projecting Sign (Ground Floor & Above Ground Floor) | A | 4 sq. ft. | 1 per lot | Not Eligible | |||
| Provisional Fence Sign | A | Max. Hgt. 12 ft. | Not Eligible | ||||
| Wall Sign (Ground Floor & Above Ground Floor) | A | 18 sq. ft. | 1 per lot | Not Eligible | |||
| C-1 | |||||||
| A-Frame | A | 8 sq. ft. per side | Max. Hgt. 4 ft. | 1 per lot | Not Eligible | ||
| Attention-Getting Device | A | Not Eligible | |||||
| Awning or Canopy Sign & Open-Structural Framework Sign | A | 2 sq. ft. per linear foot of awning, canopy, or frame width | 1 per lot | X | 25% | Per Approved Signage Plan | |
| Banner Sign (Projecting) | A | 12 sq. ft. | 1 per interior lot, 2 per corner lot | X | 25% | Per Approved Signage Plan | |
| Billboard | ASSC Only | Requirements per § 17-406 | |||||
| Electronic Sign (Category I) | A | 15 sq. ft. | Per sign type used | 1 per lot | X | 25% | Per Approved Signage Plan |
| Freestanding (Monument) | A | 32 sq. ft. | Max. Hgt. 6 ft. | 1 per lot | X | 25% | Per Approved Signage Plan |
| Painted / Mural Sign | A | 36 sq. ft. | 1 per lot | X | 25% | Per Approved Signage Plan | |
| Projecting Sign (Ground Floor) | A | 6 sq. ft. | 1 per tenant w/ direct ground-floor access | X | 25% | Per Approved Signage Plan | |
| Projecting Sign (Above Ground Floor) | A | 12 sq. ft. | 1 per lot | X | 25% | Per Approved Signage Plan | |
| Provisional Fence Sign | A | Max. Hgt. 12 ft. | Not Eligible | ||||
| Wall Sign (Ground Floor) | A | 24 sq. ft. | 1 per tenant w/ direct ground floor access/ corner tenant, 1 per street frontage | X | 25% | Per Approved Signage Plan | |
| Wall Sign (Above Ground Floor) | A | 1.5 sq. ft. per linear foot of building frontage | 1 per interior lot, 2 per corner lot | X | 25% | Per Approved Signage Plan | |
| Window Sign | A | No more than 25% of each window area | Ground floor only | 1 window per street frontage | X | 25% | Per Approved Signage Plan |
| C-1-E | |||||||
| A-Frame | A | 8 sq. ft. per side | Max. Hgt. 4 ft. | 1 per lot | Not Eligible | ||
| Attention-Getting Device | A | Not Eligible | |||||
| Awning or Canopy Sign & Open-Structural Framework Sign | A | 2 sq. ft. per linear foot of awning, canopy, or frame width | 1 per lot | X | 25% | Per Approved Signage Plan | |
| Banner Sign (Projecting) | A | 12 sq. ft. | 1 per interior lot, 2 per corner lot | X | 25% | Per Approved Signage Plan | |
| Billboard | ASSC Only | Requirements per § 17-406 | |||||
| Electronic Sign (Category I) | A | 15 sq. ft. | Per sign type used | 1 per lot | X | 25% | Per Approved Signage Plan |
| Freestanding (Monument) | A | 32 sq. ft. | Max. Hgt. 6 ft. | 1 per lot | X | 25% | Per Approved Signage Plan |
| Painted / Mural Sign | A | 36 sq. ft. | 1 per lot | X | 25% | Per Approved Signage Plan | |
| Projecting Sign (Ground Floor) | A | 6 sq. ft. | 1 per lot | X | 25% | Per Approved Signage Plan | |
| Projecting Sign (Above Ground Floor) | A | 12 sq. ft. | 1 per lot | X | 25% | Per Approved Signage Plan | |
| Provisional Fence Sign | A | Max. Hgt. 12 ft. | Not Eligible | ||||
| Wall Sign (Ground Floor & Above Ground Floor) | A | 1.5 sq. ft. per linear foot of building frontage | 1 per interior lot, 2 per corner lot | X | 25% | Per Approved Signage Plan | |
| Window Sign | A | No more than 25% of each window area | Ground floor and second floor only | 2 windows per street frontage | X | 25% | Per Approved Signage Plan |
| C-1-VC | |||||||
| A-Frame | A | 8 sq. ft. per side | Max. Hgt. 4 ft. | 1 per lot | Not Eligible | ||
| Attention-Getting Device | A | Not Eligible | |||||
| Awning or Canopy Sign & Open-Structural Framework Sign | A | 2 sq. ft. per linear foot of awning, canopy, or frame width | 1 per lot | X | 20% | Per Approved Signage Plan | |
| Banner Sign (Projecting) | A | 12 sq. ft. | 1 per interior lot, 2 per corner lot | X | 20% | Per Approved Signage Plan | |
| Billboard | ASSC Only | Requirements per § 17-406 | |||||
| Electronic Sign (Category I) | A | 15 sq. ft. | Per sign type used | 1 per lot | X | 20% | Per Approved Signage Plan |
| Freestanding (Monument) | A | 32 sq. ft. | Max. Hgt. 6 ft. | 1 per lot | X | 20% | Per Approved Signage Plan |
| Painted / Mural Sign | A | 36 sq. ft. | 1 per lot | X | 25% | Per Approved Signage Plan | |
| Projecting Sign (Ground Floor) | A | 6 sq. ft. | 1 per tenant w/ direct ground-floor access | X | 20% | Per Approved Signage Plan | |
| Provisional Fence Sign | A | Max. Hgt. 12 ft. | X | 20% | Per Approved Signage Plan | ||
| Wall Sign (Ground Floor) | A | 24 sq. ft. | 1 per tenant w/ direct ground floor access/ corner tenant, 1 per street frontage | X | 25% | Per Approved Signage Plan | |
| Wall Sign (Above Ground Floor) | A | 1.5 sq. ft. per linear foot of building frontage | 1 per interior lot, 2 per corner lot | X | 25% | Per Approved Signage Plan | |
| Window Sign | A | No more than 25% of each window area | Ground floor only | 1 window per street frontage | X | 20% | Per Approved Signage Plan |
| C-2 | |||||||
| A-Frame | A | 8 sq. ft. per side | Max. Hgt. 4 ft. | 1 per tenant w/ direct ground-floor access / Corner tenant, 1 per street frontage | Not Eligible | ||
| Attention-Getting Device | A | Not Eligible | |||||
| Awning or Canopy Sign & Open-Structural Framework Sign | A | 2 sq. ft. per linear foot of awning, canopy, or frame width | 1 per lot | X | 50% | Per Approved Signage Plan | |
| Banner Sign (Projecting) | A | 24 sq. ft. | 1 per lot | X | 50% | Per Approved Signage Plan | |
| Billboard | ASSC Only | Requirements per § 17-406 | |||||
| Electronic Sign (Category I) | A | 15 sq. ft. | Per sign type used | 1 per lot | X | 50% | Per Approved Signage Plan |
| Electronic Sign (Category II) | CB | 50 sq. ft. | Per sign type used | 2 per lot | X | 50% | Per Approved Signage Plan |
| Electronic Sign (Category III) | ASSC Only | 300 sq. ft. | Per sign type used | X | 50% | Per Approved Signage Plan | |
| Freestanding (Monument) | A | 32 sq. ft. | Max. Hgt. 6 ft. | 1 per lot | X | 50% | Per Approved Signage Plan |
| Freestanding (Pole) | A | 16 sq. ft. | Minimum. Pole Hgt. 10 ft./ Max. Sign Hgt. 6 ft. | 1 per lot | X | 50% | Per Approved Signage Plan |
| Painted / Mural Sign | A | 40 sq. ft. | 1 per lot | X | 50% | Per Approved Signage Plan | |
| Projecting Sign (Ground Floor) | A | 6 sq. ft. | 1 per tenant w/ direct ground-floor access | X | 50% | Per Approved Signage Plan | |
| Projecting Sign (Above Ground Floor) | A | 12 sq. ft. | 1 per lot | X | 50% | Per Approved Signage Plan | |
| Provisional Fence Sign | A | Max. Hgt. 12 ft. | Not Eligible | ||||
| Wall Sign (Ground Floor) | A | 30 sq. ft. | 1 per tenant w/ direct ground-floor access / Corner tenant, 1 per street frontage | X | 50% | Per Approved Signage Plan | |
| Wall Sign (Above Ground Floor) | A | 2 sq. ft. per linear foot of building frontage | 1 per interior lot, 2 per corner lot | X | 50% | Per Approved Signage Plan | |
| Window Sign | A | No more than 25% of each window area | Ground floor and second floor only | 2 windows per street frontage | X | 50% | Per Approved Signage Plan |
| C-3 | |||||||
| A-Frame | A | 8 sq. ft. per side | Max. Hgt. 4 ft. | 1 per tenant w/ direct ground-floor access / Corner tenant, 1 per street frontage | Not Eligible | ||
| Attention-Getting Device | A | Not Eligible | |||||
| Awning or Canopy Sign & Open-Structural Framework Sign | A | 2 sq. ft. per linear foot of awning, canopy, or frame width | 2 per lot | X | 50% | Per Approved Signage Plan | |
| Banner Sign (Projecting) | A | 32 sq. ft. | 2 per lot | X | 50% | Per Approved Signage Plan | |
| Billboard | ASSC Only | Requirements per § 17-406 | |||||
| Electronic Sign (Category II) | A | 50 sq. ft. | Per sign type used | 2 per lot | X | 50% | Per Approved Signage Plan |
| Freestanding (Monument) | A | 50 sq. ft. | Max. Hgt. 6 ft. | 1 per lot | X | 50% | Per Approved Signage Plan |
| Freestanding (Pole) | A | 32 sq. ft. | Minimum Pole Hgt. 10 ft./ Max. Sign Hgt. 20 ft. | 1 per lot | X | 50% | Per Approved Signage Plan |
| Freestanding (Pylon) | A | 50 sq. ft. | Minimum Hgt. 6 ft./ Max. Sign Hgt. 20 ft./ Max. Width 6 ft. | 1 per lot | X | 50% | Per Approved Signage Plan |
| Painted / Mural Sign | A | 100 sq. ft. | 1 per lot | X | 50% | Per Approved Signage Plan | |
| Projecting Sign (Ground Floor) | A | 6 sq. ft. | 1 per tenant w/ direct ground-floor access | X | 50% | Per Approved Signage Plan | |
| Projecting Sign (Above Ground Floor) | A | 18 sq. ft. | 1 per building | X | 50% | Per Approved Signage Plan | |
| Provisional Fence Sign | A | Max. Hgt. 12 ft. | Not Eligible | ||||
| Wall Sign (Ground Floor) | A | 40 sq. ft. | 1 per tenant w/ direct ground-floor access / Corner tenant, 1 per street frontage | X | 50% | Per Approved Signage Plan | |
| Wall Sign (Above Ground Floor) | A | 2 sq. ft. per linear foot of building frontage | 1 per interior lot, 2 per corner lot | X | 50% | Per Approved Signage Plan | |
| Window Sign | A | No more than 25% of each window area | Ground floor and second floor only | 2 windows per street frontage | X | 50% | Per Approved Signage Plan |
| C-4 | |||||||
| A-Frame | A | 8 sq. ft. per side | Max. Hgt. 4 ft. | 1 per tenant w/ direct ground-floor access / Corner tenant, 1 per street frontage | Not Eligible | ||
| Attention-Getting Device | A | Not Eligible | |||||
| Awning or Canopy Sign & Open-Structural Framework Sign | A | 2 sq. ft. per linear foot of awning, canopy, or frame width | 2 per lot | X | 50% | Per Approved Signage Plan | |
| Banner Sign (Projecting) | A | 32 sq. ft. | 1 per lot | X | 50% | Per Approved Signage Plan | |
| Billboard | ASSC Only | Requirements per § 17-406 | |||||
| Electronic Sign (Category II) | A | 50 sq. ft. | Per sign type used | 2 per lot | X | 50% | Per Approved Signage Plan |
| Freestanding (Monument) | A | 50 sq. ft. | Max. Hgt. 6 ft. | 1 per lot | X | 50% | Per Approved Signage Plan |
| Freestanding (Pole) | A | 32 sq. ft. | Minimum Pole Hgt. 10 ft ./ Max. Sign Hgt. 20 ft. | 1 per lot | X | 50% | Per Approved Signage Plan |
| Freestanding (Pylon) | A | 50 sq. ft. | Minimum Hgt. 6 ft./ Max. Sign Hgt. 20 ft./ Max. Width 6 ft. | 1 per lot | X | 50% | Per Approved Signage Plan |
| Painted / Mural Sign | A | 100 sq. ft. | 1 per lot | X | 50% | Per Approved Signage Plan | |
| Projecting Sign (Ground Floor) | A | 24 sq. ft. | 1 per tenant w/ direct ground-floor access | X | 50% | Per Approved Signage Plan | |
| Projecting Sign (Above Ground Floor) | A | 18 sq. ft. | 1 per building | X | 50% | Per Approved Signage Plan | |
| Provisional Fence Sign | A | Max. Hgt. 12 ft. | Not Eligible | ||||
| Wall Sign (Ground Floor) | A | 40 sq. ft. | 1 per tenant w/ direct ground-floor access | X | 50% | Per Approved Signage Plan | |
| Wall Sign (Above Ground Floor) | A | 2 sq. ft. per linear foot of building frontage | 1 per interior lot, 2 per corner lot | X | 50% | Per Approved Signage Plan | |
| Window Sign | A | No more than 25% of each window area | Ground floor and second floor only | 2 windows per street frontage | X | 50% | Per Approved Signage Plan |
| C-5-DC | |||||||
| A-Frame | A | 8 sq. ft. per side | Max. Hgt. 4 ft. | 1 per tenant w/ direct ground-floor access / Corner tenant, 1 per street frontage | Not Eligible | ||
| Attention-Getting Device | A | Not Eligible | |||||
| Awning or Canopy Sign & Open-Structural Framework Sign | A | 2 sq. ft. per linear foot of awning, canopy, or frame width | 2 per lot | X | 75% | Per Approved Signage Plan | |
| Banner Sign (Freestanding) | A | 32 sq. ft. | Max. Hgt. 6 Ft., except flags on single pole Max. Hgt. 25 ft. | 1 per lot | X | 75% | Per Approved Signage Plan |
| Banner Sign (Projecting) | A | 32 sq. ft. | 4 per lot | X | 75% | Per Approved Signage Plan | |
| Banner Sign (Wall Mounted) | A | 120 sq. ft. | Below parapet | 1 per lot | X | 75% | Per Approved Signage Plan |
| Billboard | ASSC Only | Requirements per § 17-406 | |||||
| Electronic Sign (Category I) | A | 15 sq. ft. | Per sign type used | 1 per lot | X | 75% | Per Approved Signage Plan |
| Electronic Sign (Category II) | A | 50 sq. ft. | Per sign type used | 2 per lot | X | 75% | Per Approved Signage Plan |
| Electronic Sign (Category III) | ASSC Only | 750 sq. ft. | Per sign type used | X | 75% | Per Approved Signage Plan | |
| Electronic Sign (Category IV) | ASSC Only | 5,000 sq. ft. | Per sign type used | X | 75% | Per Approved Signage Plan | |
| Electronic Sign (Category V) | ASSC Only | 10,5000 sq. ft. | Per sign type used | X | 75% | Per Approved Signage Plan | |
| Freestanding (Monument) | A | 50 sq. ft. | Max. Hgt. 6 ft. | 1 per lot | X | 75% | Per Approved Signage Plan |
| Freestanding (Pole) | ASSC Only | 700 sq. ft. | Min. Hgt. 10 ft. Max Hgt. 75 ft. in a parking lot less than 2,000ft. From a stadium with a seating capacity of at least 40,000 | 1 per lot | X | 75% | Per Approved Signage Plan |
| Freestanding (Pylon) | A | 50 sq. ft. | Minimum Hgt. 6 ft./ Max. Sign Hgt. 20 ft./ Max. Width 6 ft. | 1 per lot | X | 75% | Per Approved Signage Plan |
| Painted / Mural Sign | A | 100 sq. ft. | 1 per lot | X | 75% | Per Approved Signage Plan | |
| Projecting Sign (Ground Floor) | A | 12 sq. ft. | 1 per tenant w/ direct ground-floor access / Corner tenant, 1 per street frontage | X | 75% | Per Approved Signage Plan | |
| Projecting Sign (Above Ground Floor) | A | 250 sq. ft. | 1 per street frontage | X | 75% | Per Approved Signage Plan | |
| Provisional Fence Sign | A | Max. Hgt. 12 ft. | Not Eligible | ||||
| Roof Sign | A | 4 sq. ft. per linear foot of building frontage | May not project any higher than 20 ft. above the roof | 1 per building | X | 75% | Per Approved Signage Plan |
| Wall Sign (Ground Floor) | A | 40 sq. ft. | 1 per tenant w/ direct ground-floor access / Corner tenant, 1 per street frontage | X | 50% | Per Approved Signage Plan | |
| Wall Sign (Above Ground Floor) | A | 4 sq. ft. per linear foot of building frontage | 2 per lot | X | 75% | Per Approved Signage Plan | |
| Window Sign | A | No more than 50% of each window area | Ground floor and second floor only | X | 75% | Per Approved Signage Plan | |
| C-5-IH | |||||||
| A-Frame | A | 8 sq. ft. per side | Max. Hgt. 4 ft. | 1 per tenant w/ direct ground-floor access / Corner tenant, 1 per street frontage | Not Eligible | ||
| Attention-Getting Device | A | Not Eligible | |||||
| Awning or Canopy Sign & Open-Structural Framework Sign | A | 2 sq. ft. per linear foot of awning, canopy, or frame width | 2 per lot | X | 75% | Per Approved Signage Plan | |
| Banner Sign (Freestanding) | A | 32 sq. ft. | Max. Hgt. 6 Ft., except flags on single pole Max. Hgt. 25 ft. | 1 per lot | X | 75% | Per Approved Signage Plan |
| Banner Sign (Projecting) | A | 32 sq. ft. | 4 per lot | X | 75% | Per Approved Signage Plan | |
| Banner Sign (Wall Mounted) | A | 120 sq. ft. | Below parapet | 2 per lot | X | 75% | Per Approved Signage Plan |
| Billboard | ASSC Only | Requirements per § 17-406 | |||||
| Electronic Sign (Category I) | A | 15 sq. ft. | Per sign type used | 1 per lot | X | 75% | Per Approved Signage Plan |
| Electronic Sign (Category II) | A | 50 sq. ft. | Per sign type used | 2 per lot | X | 75% | Per Approved Signage Plan |
| Electronic Sign (Category III) | ASSC Only | 750 sq. ft. | Per sign type used | X | 75% | Per Approved Signage Plan | |
| Freestanding (Monument) | A | 50 sq. ft. | Max. Hgt. 6 ft. | 1 per lot | X | 75% | Per Approved Signage Plan |
| Freestanding (Pylon) | A | 50 sq. ft. | Minimum Hgt. 6 ft./ Max. Sign Hgt. 20 ft./ Max. Width 6 ft. | 1 per lot | X | 75% | Per Approved Signage Plan |
| Painted / Mural Sign | A | 100 sq. ft. | 1 per lot | X | 75% | Per Approved Signage Plan | |
| Projecting Sign (Ground Floor) | A | 15 sq. ft. | 1 per tenant w/ direct ground-floor access / Corner tenant, 1 per street frontage | X | 75% | Per Approved Signage Plan | |
| Projecting Sign (Above Ground Floor) | A | 60 sq. ft. | 1 per street frontage | X | 75% | Per Approved Signage Plan | |
| Provisional Fence Sign | A | Max. Hgt. 12 ft. | Not Eligible | ||||
| Roof Sign | A | 4 sq. ft. per linear foot of building frontage | May not project any higher than 20 ft. above the roof | 1 per building | X | 75% | Per Approved Signage Plan |
| Wall Sign (Ground Floor) | A | 40 sq. ft. | 1 per tenant w/ direct ground-floor access / Corner tenant, 1 per street frontage | X | 75% | Per Approved Signage Plan | |
| Wall Sign (Above Ground Floor) | A | 4 sq. ft. per linear foot of building frontage | 2 per lot | X | 50% | Per Approved Signage Plan | |
| Window Sign | A | No more than 50% of each window area | Ground floor and second floor only | X | 75% | Per Approved Signage Plan | |
| C-5-DE | |||||||
| A-Frame | A | 8 sq. ft. per side | Max. Hgt. 4 ft. | 1 per tenant w/ direct ground-floor access / Corner tenant, 1 per street frontage | Not Eligible | ||
| Attention-Getting Device | A | Not Eligible | |||||
| Awning or Canopy Sign & Open-Structural Framework Sign | A | 2 sq. ft. per linear foot of awning, canopy, or frame width | 2 per lot | X | 75% | Per Approved Signage Plan | |
| Banner Sign (Freestanding) | A | 32 sq. ft. | 1 per lot | X | 75% | Per Approved Signage Plan | |
| Banner Sign (Projecting) | A | 32 sq. ft. | 4 per lot | X | 75% | Per Approved Signage Plan | |
| Banner Sign (Wall Mounted) | A | 120 sq. ft. | Below parapet | 2 per lot | X | 75% | Per Approved Signage Plan |
| Billboard | ASSC Only | Requirements per § 17-406 | |||||
| Electronic Sign (Category I) | A | 15 sq. ft. | Per sign type used | 1 per lot | X | 75% | Per Approved Signage Plan |
| Electronic Sign (Category II) | A | 50 sq. ft. | Per sign type used | 2 per lot | X | 75% | Per Approved Signage Plan |
| Electronic Sign (Category III) | ASSC Only | 750 sq. ft. | Per sign type used | X | 75% | Per Approved Signage Plan | |
| Freestanding (Monument) | A | 50 sq. ft. | Max. Hgt. 6 ft. | 1 per lot | X | 75% | Per Approved Signage Plan |
| Freestanding (Pylon) | A | 50 sq. ft. | Minimum Hgt. 6 ft./ Max. Sign Hgt. 20 ft./ Max. Width 6 ft. | 1 per lot | X | 75% | Per Approved Signage Plan |
| Painted / Mural Sign | A | 100 sq. ft. | 1 per lot | X | 75% | Per Approved Signage Plan | |
| Projecting Sign (Ground Floor) | A | 15 sq. ft. | 1 per tenant w/ direct ground-floor access / Corner tenant, 1 per street frontage | X | 75% | Per Approved Signage Plan | |
| Projecting Sign (Above Ground Floor) | A | 60 sq. ft. | 1 per street frontage | X | 75% | Per Approved Signage Plan | |
| Provisional Fence Sign | A | Max. Hgt. 12 ft. | Not Eligible | ||||
| Roof Sign | A | 4 sq. ft. per linear foot of building frontage | May not project any higher than 20 ft. above the roof | 1 per building | X | 75% | Per Approved Signage Plan |
| Wall Sign (Ground Floor) | A | 40 sq. ft. | 1 per tenant w/ direct ground-floor access / Corner tenant, 1 per street frontage | X | 50% | Per Approved Signage Plan | |
| Wall Sign (Above Ground Floor) | A | 4 sq. ft. per linear foot of building frontage | 2 per lot | X | 50% | Per Approved Signage Plan | |
| Window Sign | A | No more than 50% of each window area | Ground floor and second floor only | X | 50% | Per Approved Signage Plan | |
| C-5-HT | |||||||
| A-Frame | A | 8 sq. ft. per side | Max. Hgt. 4 ft. | 1 per tenant w/ direct ground-floor access / Corner tenant, 1 per street frontage | Not Eligible | ||
| Attention-Getting Device | A | Not Eligible | |||||
| Awning or Canopy Sign & Open-Structural Framework Sign | A | 2 sq. ft. per linear foot of awning, canopy, or frame width | 2 per lot | X | 50% | Per Approved Signage Plan | |
| Banner Sign (Freestanding) | A | 32 sq. ft. | Max . Hgt. 6 ft., except flags on single pole Max. Hgt. 25 ft. | 1 per lot | X | 50% | Per Approved Signage Plan |
| Banner Sign (Projecting) | A | 50 sq. ft. | 4 per lot | X | 50% | Per Approved Signage Plan | |
| Banner Sign (Wall Mounted) | A | 120 sq. ft. | Below parapet | 2 per lot | X | 50% | Per Approved Signage Plan |
| Billboard | ASSC Only | Requirements per § 17-406 | |||||
| Electronic Sign (Category I) | A | 15 sq. ft. | Per sign type used | 1 per lot | X | 50% | Per Approved Signage Plan |
| Electronic Sign (Category II) | A | 50 sq. ft. | Per sign type used | 2 per lot | X | 50% | Per Approved Signage Plan |
| Freestanding (Monument) | A | 50 sq. ft. | Max. Hgt. 6 ft. | 1 per lot | X | 50% | Per Approved Signage Plan |
| Freestanding (Pylon) | A | 50 sq. ft. | Minimum Hgt. 6 ft./ Max. Sign Hgt. 20 ft./ Max. Width 6 ft. | 1 per lot | X | 50% | Per Approved Signage Plan |
| Painted / Mural Sign | A | 60 sq. ft. | 1 per lot | X | 50% | Per Approved Signage Plan | |
| Projecting Sign (Ground Floor) | A | 12 sq. ft. | 1 per tenant w/ direct ground-floor access / Corner tenant, 1 per street frontage | X | 50% | Per Approved Signage Plan | |
| Projecting Sign (Above Ground Floor) | A | 60 sq. ft. | 1 per street frontage | X | 50% | Per Approved Signage Plan | |
| Provisional Fence Sign | A | Max. Hgt. 12 ft. | Not Eligible | ||||
| Roof Sign | A | 2 sq. ft. per linear foot of building frontage | May not project any higher than 20 ft. above the roof | 1 per building | X | 50% | Per Approved Signage Plan |
| Wall Sign (Ground Floor) | A | 25 sq. ft. | 1 per tenant w/ direct ground-floor access / Corner tenant, 1 per street frontage | X | 25% | Per Approved Signage Plan | |
| Wall Sign (Above Ground Floor) | A | 4 sq. ft. per linear foot of building frontage | 2 per lot | X | 25% | Per Approved Signage Plan | |
| Window Sign | A | No more than 50% of each window area | Ground floor and second floor only | X | 25% | Per Approved Signage Plan | |
| C-5-TO | |||||||
| A-Frame | A | 8 sq. ft. per side | Max. Hgt. 4 ft. | 1 per tenant w/ direct ground-floor access / Corner tenant, 1 per street frontage | Not Eligible | ||
| Attention-Getting Device | A | Not Eligible | |||||
| Awning or Canopy Sign & Open-Structural Framework Sign | A | 2 sq. ft. per linear foot of awning, canopy, or frame width | 2 per lot | X | 50% | Per Approved Signage Plan | |
| Banner Sign (Freestanding) | A | 32 sq. ft. | Max. Hgt. 6 ft., except flags on single pole Max. Hgt. 25 ft. | 1 per lot | X | 50% | Per Approved Signage Plan |
| Banner Sign (Projecting) | A | 50 sq. ft. | 4 per lot | X | 50% | Per Approved Signage Plan | |
| Banner Sign (Wall Mounted) | A | 120 sq. ft. | Below parapet | 1 per lot | X | 50% | Per Approved Signage Plan |
| Billboard | ASSC Only | Requirements per § 17-406 | |||||
| Electronic Sign (Category I) | A | 15 sq. ft. | Per sign type used | 1 per lot | X | 50% | Per Approved Signage Plan |
| Electronic Sign (Category II) | A | 50 sq. ft. | Per sign type used | 2 per lot | X | 50% | Per Approved Signage Plan |
| Electronic Sign (Category III) | ASSC Only | 750 sq. ft. | Per sign type used | X | 50% | Per Approved Signage Plan | |
| Electronic Sign (Category IV) | ASSC Only | 5,000 sq. ft. | Per sign type used | X | 50% | Per Approved Signage Plan | |
| Freestanding (Monument) | A | 50 sq. ft. | Max. Hgt. 6 ft. | 1 per lot | X | 50% | Per Approved Signage Plan |
| Freestanding (Pylon) | A | 50 sq. ft. | Minimum Hgt. 6 ft./ Max. Sign Hgt. 20 ft./ Max. Width 6 ft. | 1 per lot | X | 50% | Per Approved Signage Plan |
| Painted / Mural Sign | A | 100 sq. ft. | 1 per lot | X | 50% | Per Approved Signage Plan | |
| Projecting Sign (Ground Floor) | A | 15 sq. ft. | 1 per tenant w/ direct ground-floor access / Corner tenant, 1 per street frontage | X | 50% | Per Approved Signage Plan | |
| Projecting Sign (Above Ground Floor) | A | 60 sq. ft. | 1 per street frontage | X | 50% | Per Approved Signage Plan | |
| Provisional Fence Sign | A | Max. Hgt. 12 ft. | Not Eligible | ||||
| Roof Sign | A | 2 sq. ft. per linear foot of building frontage | May not project any higher than 20 ft. above the roof | 1 per building | X | 50% | Per Approved Signage Plan |
| Wall Sign (Ground Floor) | A | 40 sq. ft. | 1 per tenant w/ direct ground-floor access / Corner tenant, 1 per street frontage | X | 25% | Per Approved Signage Plan | |
| Wall Sign (Above Ground Floor) | A | 4 sq. ft. per linear foot of building frontage | 2 per lot | X | 25% | Per Approved Signage Plan | |
| Window Sign | A | No more than 40% of each window area | Ground floor and second floor only | X | 25% | Per Approved Signage Plan | |
| C-5-HS | |||||||
| A-Frame | A | 8 sq. ft. per side | Max. Hgt. 4 ft. | 1 per tenant w/ direct ground-floor access / Corner tenant, 1 per street frontage | Not Eligible | ||
| Attention-Getting Device | A | Not Eligible | |||||
| Awning or Canopy Sign & Open-Structural Framework Sign | A | 2 sq. ft. per linear foot of awning, canopy, or frame width | 2 per lot | X | 50% | Per Approved Signage Plan | |
| Banner Sign (Freestanding) | A | 32 sq. ft. | Max. Hgt. 6 ft., except flags on single pole Max. Hgt. 25 ft. | 1 per lot | X | 50% | Per Approved Signage Plan |
| Banner Sign (Projecting) | A | 50 sq. ft. | 4 per lot | X | 50% | Per Approved Signage Plan | |
| Billboard | ASSC Only | Requirements per § 17-406 | |||||
| Electronic Sign (Category I) | A | 15 sq. ft. | Per sign type used | 1 per lot | X | 50% | Per Approved Signage Plan |
| Electronic Sign (Category II) | A | 50 sq. ft. | Per sign type used | 2 per lot | X | 50% | Per Approved Signage Plan |
| Electronic Sign (Category III) | ASSC Only | 400 sq. ft. | Per sign type used | X | 50% | Per Approved Signage Plan | |
| Freestanding (Monument) | A | 50 sq. ft. | Max. Hgt. 8 ft. | 1 per lot | X | 50% | Per Approved Signage Plan |
| Freestanding (Pylon) | A | 50 sq. ft. | Minimum Hgt. 6 ft./ Max. Sign Hgt. 20 ft./ Max. Width 6 ft. | 1 per lot | X | 50% | Per Approved Signage Plan |
| Painted / Mural Sign | A | 100 sq. ft. | 1 per lot | X | 50% | Per Approved Signage Plan | |
| Projecting Sign (Ground Floor) | A | 15 sq. ft. | 1 per tenant w/ direct ground-floor access / Corner tenant, 1 per street frontage | X | 50% | Per Approved Signage Plan | |
| Projecting Sign (Above Ground Floor) | A | 60 sq. ft. | 1 per street frontage | X | 50% | Per Approved Signage Plan | |
| Provisional Fence Sign | A | Max. Hgt. 12 ft. | Not Eligible | ||||
| Roof Sign | A | 2 sq. ft. per linear foot of building frontage | May not project any higher than 15 ft. above the roof | 1 per building | X | 50% | Per Approved Signage Plan |
| Wall Sign (Ground Floor) | A | 40 sq. ft. | 1 per tenant w/ direct ground-floor access / Corner tenant, 1 per street frontage | X | 25% | Per Approved Signage Plan | |
| Wall Sign (Above Ground Floor) | A | 4 sq. ft. per linear foot of building frontage | 2 per lot | X | 25% | Per Approved Signage Plan | |
| Window Sign | A | No more than 40% of each window area | Ground floor and second floor only | X | 25% | Per Approved Signage Plan | |
| C-5-G | |||||||
| A-Frame | A | 8 sq. ft. per side | Max. Hgt. 4 ft. | 1 per tenant w/ direct ground-floor access / Corner tenant, 1 per street frontage | Not Eligible | ||
| Attention-Getting Device | A | Not Eligible | |||||
| Awning or Canopy Sign & Open-Structural Framework Sign | A | 2 sq. ft. per linear foot of awning, canopy, or frame width | 2 per lot | X | 50% | Per Approved Signage Plan | |
| Banner Sign (Freestanding) | A | 32 sq. ft. | Max. Hgt. 6 ft., except flags on single pole Max. Hgt. 25 ft. | 1 per lot | X | 50% | Per Approved Signage Plan |
| Banner Sign (Projecting) | A | 50 sq. ft. | 4 per lot | X | 50% | Per Approved Signage Plan | |
| Banner Sign (Wall Mounted) | A | 120 sq. ft. | Below parapet | 1 per lot | X | 50% | Per Approved Signage Plan |
| Billboard | ASSC Only | Requirements per § 17-406 | |||||
| Electronic Sign (Category I) | A | 15 sq. ft. | Per sign type used | 1 per lot | X | 50% | Per Approved Signage Plan |
| Electronic Sign (Category II) | A | 50 sq. ft. | Per sign type used | 2 per lot | X | 50% | Per Approved Signage Plan |
| Electronic Sign (Category III) | ASSC Only | 750 sq. ft. | Per sign type used | X | 50% | Per Approved Signage Plan | |
| Freestanding (Monument) | A | 50 sq. ft. | Max. Hgt. 6 ft. | 1 per lot | X | 50% | Per Approved Signage Plan |
| Freestanding (Pylon) | A | 50 sq. ft. | Minimum Hgt. 6 ft./ Max. Sign Hgt. 20 ft./ Max. Width 6 ft. | 1 per lot | X | 50% | Per Approved Signage Plan |
| Painted / Mural Sign | A | 100 sq. ft. | 1 per lot | X | 50% | Per Approved Signage Plan | |
| Projecting Sign (Ground Floor) | A | 15 sq. ft. | 1 per tenant w/ direct ground-floor access / Corner tenant, 1 per street frontage | X | 50% | Per Approved Signage Plan | |
| Projecting Sign (Above Ground Floor) | A | 60 sq. ft. | 1 per street frontage | X | 50% | Per Approved Signage Plan | |
| Provisional Fence Sign | A | Max. Hgt. 12 ft. | X | 50% | Per Approved Signage Plan | ||
| Roof Sign | A | 4 sq. ft. per linear foot of building frontage | May not project any higher than 20 ft. above the roof | 1 per building | X | 50% | Per Approved Signage Plan |
| Wall Sign (Ground Floor) | A | 40 sq. ft. | 1 per tenant w/ direct ground-floor access | X | 25% | Per Approved Signage Plan | |
| Wall Sign (Above Ground Floor) | A | 4 sq. ft. per linear foot of building frontage | 2 per lot | X | 25% | Per Approved Signage Plan | |
| Window Sign | A | No more than 40% of each window area | Ground floor and second floor only | X | 25% | Per Approved Signage Plan | |
| OIC | |||||||
| Attention-Getting Device | A | Not Eligible | |||||
| Awning or Canopy Sign & Open-Structural Framework Sign | A | 2 sq. ft. per linear foot of awning, canopy, or frame width | 2 per lot | Not Eligible | |||
| Banner Sign (Projecting) | A | 32 sq. ft. | 2 per lot | Not Eligible | |||
| Electronic Sign (Category I) | A | 15 sq. ft. | Per sign type used | 1 per lot | Not Eligible | ||
| Electronic Sign (Category II) | A | 50 sq. ft. | Per sign type used | 2 per lot | Not Eligible | ||
| Freestanding (Monument) | A | 100 sq. ft. | Max. Hgt. 6 ft. | Not Eligible | |||
| Freestanding (Pole) | A | 50 sq. ft. | Minimum Pole Hgt. 10 ft./ Max. Sign Hgt. 24 ft. | 1 per lot | |||
| Freestanding (Pylon) | A | 50 sq. ft. | Minimum Hgt. 6 ft./ Max. Sign Hgt. 20 ft./ Max. Width 6 ft. | 1 per lot | Not Eligible | ||
| Painted / Mural Sign | CB | 50 sq. ft. | 1 per lot | Not Eligible | |||
| Projecting Sign (Ground Floor) | A | 18 sq. ft. | 1 per tenant w/ direct ground-floor access / Corner tenant, 1 per street frontage | Not Eligible | |||
| Projecting Sign (Above Ground Floor) | A | 36 sq. ft. | 1 per building | Not Eligible | |||
| Provisional Fence Sign | A | Max. Hgt. 12 ft. | Not Eligible | ||||
| Wall Sign (Ground Floor & Above Ground Floor) | A | 25 sq. ft. per linear foot of building frontage | 2 per lot | Not Eligible | |||
| BSC | |||||||
| A-Frame | A | 8 sq. ft. per side | Max. Hgt. 4 ft. | 1 per tenant w/ direct ground-floor access / Corner tenant, 1 per street frontage | Not Eligible | ||
| Attention-Getting Device | A | Not Eligible | |||||
| Awning or Canopy Sign & Open-Structural Framework Sign | A | 2 sq. ft. per linear foot of awning, canopy, or frame width | 2 per lot | Not Eligible | |||
| Banner Sign (Freestanding) | A | 32 sq. ft. | Max. Hgt. 6 ft., except flags on single pole Max. Hgt. 25 ft. | 1 per lot | Not Eligible | ||
| Banner Sign (Projecting) | A | 50 sq. ft. | 4 per lot | Not Eligible | |||
| Electronic Sign (Category I) | A | 15 sq. ft. | Per sign type used | 1 per lot | Not Eligible | ||
| Electronic Sign (Category II) | A | 50 sq. ft. | Per sign type used | 2 per lot | Not Eligible | ||
| Freestanding (Monument) | A | 50 sq. ft. | Max. Hgt. 6 ft. | 1 per lot | Not Eligible | ||
| Freestanding (Pole) | A | 50 sq. ft. | Minimum Pole Hgt. 10 ft./ Max. Sign Hgt. 24 ft. | 1 per lot | Not Eligible | ||
| Freestanding (Pylon) | A | 50 sq. ft. | Minimum Hgt. 6 ft./ Max. Sign Hgt. 20 ft./ Maximum Width 6 ft. | 1 per lot | Not Eligible | ||
| Painted / Mural Sign | A | 60 sq. ft. | 1 per lot | Not Eligible | |||
| Projecting Sign (Ground Floor) | A | 18 sq. ft. | 1 per tenant w/ direct ground-floor access / Corner tenant, 1 per street frontage | Not Eligible | |||
| Projecting Sign (Above Ground Floor) | A | 48 sq. ft. | 2 per lot | Not Eligible | |||
| Provisional Fence Sign | A | Max. Hgt. 12 ft. | Not Eligible | ||||
| Wall Sign (Ground Floor) | A | 40 sq. ft. | 1 per tenant w/ direct ground-floor access / Corner tenant, 1 per street frontage | Not Eligible | |||
| Wall Sign (Above Ground Floor) | A | 2 sq. ft. per linear foot of building frontage | 1 per interior lot, 2 per corner lot | Not Eligible | |||
| Window Sign | A | No more than 40% of each window area | Ground floor and second floor only | Not Eligible | |||
| IMU-1 and IMU-2 | |||||||
| A-Frame | A | 8 sq. ft. per side | Max. Hgt. 4 ft. | 1 per tenant w/ direct ground-floor access / Corner tenant, 1 per street frontage | Not Eligible | ||
| Attention-Getting Device | A | Not Eligible | |||||
| Awning or Canopy Sign & Open-Structural Framework Sign | A | X | 50% | Per Approved Signage Plan | |||
| Banner Sign (Freestanding) | A | 32 sq. ft. | Max. Hgt. 6 ft., except flags on single pole Max. Hgt. 25 ft. | 1 per lot | X | 50% | Per Approved Signage Plan |
| Banner Sign (Projecting) | A | 20 sq. ft. | 1 per street frontage | X | 50% | Per Approved Signage Plan | |
| Banner Sign (Wall Mounted) | A | 32 sq. ft. | Below parapet | 1 per lot | X | 50% | Per Approved Signage Plan |
| Freestanding (Pole) | A | 50 sq. ft. | Minimum Pole Hgt. 10 ft./ Max. Sign Hgt. 24 ft. | 1 per lot | X | 50% | Per Approved Signage Plan |
| Freestanding (Pylon) | A | 50 sq. ft. | Minimum Hgt. 6 ft./ Max. Sign Hgt. 20 ft./ Maximum Width 6 ft. | 1 per lot | X | 50% | Per Approved Signage Plan |
| Painted / Mural Sign | A | 50 sq. ft. | 1 per lot | X | 50% | Per Approved Signage Plan | |
| Projecting Sign (Ground Floor) | A | 18 sq. ft. | 1 per tenant w/ direct ground-floor access / Corner tenant, 1 per street frontage | X | 50% | Per Approved Signage Plan | |
| Projecting Sign (Above Ground Floor) | A | 48 sq. ft. | 1 per lot | X | 50% | Per Approved Signage Plan | |
| Provisional Fence Sign | A | Max. Hgt. 12 ft. | Not Eligible | ||||
| Roof Sign | ASSC Only | 2 sq. ft. per linear foot of building frontage | May not project any higher than 20 ft. above the roof | 1 per building | X | 50% | Per Approved Signage Plan |
| Wall Sign (Ground Floor) | A | 40 sq. ft. | 1 per tenant w/ direct ground-floor access / Corner tenant, 1 per street frontage | X | 50% | Per Approved Signage Plan | |
| Wall Sign (Above Ground Floor) | A | 2 sq. ft. per linear foot of building frontage | 1 per interior lot, 2 per corner lot | X | 50% | Per Approved Signage Plan | |
| Window Sign | A | No more than 25% of each window area | Ground floor and second floor only | X | 50% | Per Approved Signage Plan | |
| I-1 | |||||||
| Attention-Getting Device | A | Not Eligible | |||||
| Freestanding (Monument) | A | 50 sq. ft. | Max. Hgt. 6 ft. | 1 per lot | Not Eligible | ||
| Freestanding (Pole) | A | 50 sq. ft. | Minimum Pole Hgt. 10 ft./ Max. Sign Hgt. 24 ft. | 1 per lot | Not Eligible | ||
| Projecting Sign (Ground Floor) | A | 18 sq. ft. | 1 per lot | Not Eligible | |||
| Provisional Fence Sign | A | Max. Hgt. 12 ft. | Not Eligible | ||||
| Wall Sign (Ground Floor & Above Ground Floor) | A | 2 sq. ft. per linear foot of building frontage | 2 per lot | Not Eligible | |||
| I-2 | |||||||
| Attention-Getting Device | A | Not Eligible | |||||
| Electronic Sign (Category II) | A | 50 sq. ft. | Per sign type used | 1 per lot | Not Eligible | ||
| Freestanding (Monument) | A | 50 sq. ft. | Max. Hgt. 6 ft. | 1 per lot | Not Eligible | ||
| Freestanding (Pole) | A | 50 sq. ft. | Minimum Pole Hgt. 10 ft./ Max. Sign Hgt. 24 ft. | 1 per lot | Not Eligible | ||
| Projecting Sign (Ground Floor) | A | 18 sq. ft. | 1 per lot | Not Eligible | |||
| Provisional Fence Sign | A | Max. Hgt. 12 ft. | Not Eligible | ||||
| Roof Sign | A | 2 sq. ft. per linear foot of building frontage | May not project any higher than 20 ft. above the roof | 1 per building | Not Eligible | ||
| Wall Sign (Ground Floor & Above Ground Floor) | A | 2 sq. ft. per linear foot of building frontage | 1 per interior lot, 2 per corner lot | Not Eligible | |||
| MI | |||||||
| Attention-Getting Device | A | Not Eligible | |||||
| Electronic Sign (Category II) | A | 50 sq. ft. | Per sign type used | 2 per lot | Not Eligible | ||
| Freestanding (Monument) | A | 50 sq. ft. | Max. Hgt. 6 ft. | 1 per lot | Not Eligible | ||
| Freestanding (Pole) | A | 50 sq. ft. | Minimum Pole Hgt. 10 ft./ Max. Sign Hgt. 24 ft. | 1 per lot | Not Eligible | ||
| Projecting Sign (Ground Floor & Above Ground Floor) | A | 24 sq. ft. | 2 per lot | Not Eligible | |||
| Provisional Fence Sign | A | Max. Hgt. 12 ft. | Not Eligible | ||||
| Roof Sign | A | 2 sq. ft. per linear foot of building frontage | May not project any higher than 20 ft. above the roof | 1 per building | Not Eligible | ||
| Wall Sign (Ground Floor & Above Ground Floor) | A | 2 sq. ft. per linear foot of building frontage | 1 per interior lot, 2 per corner lot | Not Eligible | |||
| OR-1 | |||||||
| Awning or Canopy Sign & Open-Structural Framework Sign | A | 2 sq. ft. per linear foot of awning, canopy, or frame width | 1 per lot | X | 25% | Per Approved Signage Plan | |
| Banner Sign (Freestanding) | A | 32 sq. ft. | Max. Hgt. 6 ft., except flags on single pole Max. Hgt. 25 ft. | 1 per lot | X | 25% | Per Approved Signage Plan |
| Banner Sign (Projecting) | A | 20 sq. ft. | 1 per lot | X | 25% | Per Approved Signage Plan | |
| Freestanding (Monument) | A | 32 sq. ft. | Max. Hgt. 6 ft. | 1 per lot | X | 25% | Per Approved Signage Plan |
| Painted / Mural Sign | CB | 40 sq. ft. | 1 per lot | X | 25% | Per Approved Signage Plan | |
| Provisional Fence Sign | A | Max. Hgt. 12 ft. | Not Eligible | ||||
| Wall Sign (Ground Floor) | A | 30 sq. ft. | 1 per tenant w/ direct ground-floor access | X | 25% | Per Approved Signage Plan | |
| Wall Sign (Above Ground Floor) | A | 1 sq. ft. per linear foot of building frontage | 1 per interior lot, 2 per corner lot | X | 25% | Per Approved Signage Plan | |
| OR-2 | |||||||
| A-Frame | A | 8 sq. ft. per side | Max. Hgt. 4 ft. | 1 per lot | Not Eligible | ||
| Awning or Canopy Sign & Open-Structural Framework Sign | A | 2 sq. ft. per linear foot of awning, canopy, or frame width | 1 per lot | X | 50% | Per Approved Signage Plan | |
| Banner Sign (Projecting) | A | 20 sq. ft. | 1 per lot | X | 50% | Per Approved Signage Plan | |
| Painted / Mural Sign | CB | 40 sq. ft. | 1 per lot | X | 50% | Per Approved Signage Plan | |
| Provisional Fence Sign | A | Max. Hgt. 12 ft. | Not Eligible | ||||
| Wall Sign (Ground Floor) | A | 30 sq. ft. | 1 per tenant w/ direct ground-floor access | X | 50% | Per Approved Signage Plan | |
| Wall Sign (Above Ground Floor) | A | 1 sq. ft. per linear foot of building frontage | 1 per interior lot, 2 per corner lot | X | 50% | Per Approved Signage Plan | |
| EC-1 | |||||||
| Awning or Canopy Sign & Open-Structural Framework Sign | A | 2 sq. ft. per linear foot of awning, canopy, or frame width | 1 per building | Not Eligible | |||
| Banner Sign (Freestanding) | A | 32 sq. ft. | Max. Hgt. 6 ft., except flags on single pole Max. Hgt. 25 ft. | 1 per lot | Not Eligible | ||
| Banner Sign (Projecting) | A | 20 sq. ft. | 1 per building | Not Eligible | |||
| Banner Sign (Wall Mounted) | A | 32 sq. ft. | Below parapet | 1 per lot | Not Eligible | ||
| Electronic Sign (Category I) | A | 15 sq. ft. | Per sign type used | 1 per lot | Not Eligible | ||
| Electronic Sign (Category II) | A | 50 sq. ft. | Per sign type used | 2 per lot | Not Eligible | ||
| Freestanding (Monument) | A | 100 sq. ft. | Max. Hgt. 6 ft. | Not Eligible | |||
| Freestanding (Pole) | A | 32 sq. ft. | Minimum Pole Hgt. 10 ft./ Max. Sign Hgt. 20 ft. | 1 per lot | Not Eligible | ||
| Freestanding (Pylon) | A | 50 sq. ft. | Minimum Hgt. 6 ft./ Max. Sign Hgt. 20 ft. / Maximum Width 6 ft. | 1 per lot | Not Eligible | ||
| Painted / Mural Sign | A | 60 sq. ft. | 1 per lot | Not Eligible | |||
| Provisional Fence Sign | A | Max. Hgt. 12 ft. | Not Eligible | ||||
| Wall Sign (Ground Floor & Above Ground Floor) | A | 1 sq. ft. per linear foot of building frontage | 2 per building | Not Eligible | |||
| Window Sign | A | No more than 25% of each window area | Ground floor and second floor only | 2 per building | Not Eligible | ||
| EC-2 | |||||||
| A-Frame | A | 8 sq. ft. per side | Max. Hgt. 4 ft. | 1 per building | Not Eligible | ||
| Attention Getting Device | A | Not Eligible | |||||
| Awning or Canopy Sign & Open-Structural Framework Sign | A | 2 sq. ft. per linear foot of awning, canopy, or frame width | 1 per building | Not Eligible | |||
| Banner Sign (Freestanding) | A | 32 sq. ft. | Max. Hgt. 6 ft., except flags on single pole Max. Hgt. 25 ft. | 1 per lot | Not Eligible | ||
| Banner Sign (Projecting) | A | 20 sq. ft. | 1 per street frontage | Not Eligible | |||
| Banner Sign (Wall Mounted) | A | 32 sq. ft. | Below parapet | 2 per lot | Not Eligible | ||
| Electronic Sign (Category I) | A | 15 sq. ft. | Per sign type used | 1 per lot | Not Eligible | ||
| Electronic Sign (Category II) | A | 50 sq. ft. | Per sign type used | 2 per lot | Not Eligible | ||
| Freestanding (Monument) | A | 100 sq. ft. | Max. Hgt. 6 ft. | Not Eligible | |||
| Freestanding (Pylon) | A | 50 sq. ft. | Minimum Hgt. 6 ft./ Max. Sign Hgt. 20 ft. / Maximum Width 6 ft. | 1 per lot | Not Eligible | ||
| Painted / Mural Sign | A | 60 sq. ft. | 1 per lot | Not Eligible | |||
| Projecting Sign (Ground Floor) | A | 36 sq. ft. | 1 per tenant w/ direct ground-floor access / Corner tenant, 1 per street frontage | Not Eligible | |||
| Projecting Sign (Above Ground Floor) | A | 12 sq. ft. | 1 per street frontage | Not Eligible | |||
| Wall Sign (Ground Floor) | A | 18 sq. ft. | 1 per tenant w/ direct ground-floor access | Not Eligible | |||
| Wall Sign (Above Ground Floor) | A | 1 sq. ft. per linear foot of building frontage | 1 per interior lot, 2 per corner lot | Not Eligible | |||
| Window Sign | A | No more than 35% of each window area | Ground floor and second floor only | 2 windows per street frontage | Not Eligible | ||
| H | |||||||
| A-Frame | A | 8 sq. ft. per side | Max. Hgt. 4 ft. | 1 per tenant w/ direct ground-floor access / Corner tenant, 1 per street frontage | Not Eligible | ||
| Attention Getting Device | A | Not Eligible | |||||
| Awning or Canopy Sign & Open-Structural Framework Sign | A | 2 sq. ft. per linear foot of awning, canopy, or frame width | 1 per building | Not Eligible | |||
| Banner Sign (Freestanding) | A | 32 sq. ft. | Max. Hgt. 6 ft., except flags on single pole Max. Hgt. 25 ft. | 1 per lot | Not Eligible | ||
| Banner Sign (Projecting) | A | 20 sq. ft. | 1 per street frontage | Not Eligible | |||
| Banner Sign (Wall Mounted) | A | 32 sq. ft. | Below parapet | 1 per lot | Not Eligible | ||
| Electronic Sign (Category I) | A | 15 sq. ft. | Per sign type used | 1 per lot | Not Eligible | ||
| Electronic Sign (Category II) | A | 50 sq. ft. | Per sign type used | 2 per lot | Not Eligible | ||
| Freestanding (Monument) | A | 100 sq. ft. | Max. Hgt. 6 ft. | 1 per lot | Not Eligible | ||
| Freestanding (Pole) | A | 32 sq. ft. | Min. Pole Hgt. 10 ft./ Max. Sign Hgt. 20 ft. | 1 per lot | Not Eligible | ||
| Freestanding (Pylon) | A | 50 sq. ft. | Min. Hgt. 6 ft./ Max. Sign Hgt. 20 ft. / Max. Width 6 ft. | 1 per lot | Not Eligible | ||
| Painted / Mural Sign | A | 60 sq. ft. | 1 per lot | Not Eligible | |||
| Projecting Sign (Ground Floor) | A | 36 sq. ft. | 1 per street frontage | Not Eligible | |||
| Projecting Sign (Above Ground Floor) | A | 12 sq. ft. | 1 per street frontage | Not Eligible | |||
| Provisional Fence Sign | A | Max. Hgt. 12 ft. | Not Eligible | ||||
| Wall Sign (Ground Floor) | A | 40 sq. ft. | 1 per tenant w/ direct ground-floor access | Not Eligible | |||
| Wall Sign (Above Ground Floor) | A | 2 sq. ft. per linear foot of building frontage | 1 per interior lot, 2 per corner lot | Not Eligible | |||
| Window Sign | A | No more than 25% of each window area | Ground floor and second floor only | 1 window per street frontage | Not Eligible | ||
| TOD-1 | |||||||
| A-Frame | A | 8 sq. ft. per side | Max. Hgt. 4 ft. | 1 per tenant w/ direct ground-floor access / Corner tenant, 1 per street frontage | Not Eligible | ||
| Attention Getting Device | A | Not Eligible | |||||
| Awning or Canopy Sign & Open-Structural Framework Sign | A | 2 sq. ft. per linear foot of awning, canopy, or frame width | 1 per building | X | 50% | Per Approved Signage Plan | |
| Banner Sign (Freestanding) | A | 32 sq. ft. | Max. Hgt. 6 ft., except flags on single pole Max. Hgt. 25 ft. | 1 per lot | X | 50% | Per Approved Signage Plan |
| Banner Sign (Projecting) | A | 20 sq. ft. | 1 per street frontage | X | 50% | Per Approved Signage Plan | |
| Banner Sign (Wall Mounted) | A | 32 sq. ft. | Below parapet | 1 per lot | X | 50% | Per Approved Signage Plan |
| Billboard | ASSC Only | Requirements per § 17-406 | |||||
| Electronic Sign (Category I) | A | 15 sq. ft. | Per sign type used | 1 per lot | X | 50% | Per Approved Signage Plan |
| Freestanding (Monument) | A | 32 sq. ft. | Max. Hgt. 6 ft. | 1 per lot | X | 50% | Per Approved Signage Plan |
| Painted / Mural Sign | A | 40 sq. ft. | 1 per lot | X | 50% | Per Approved Signage Plan | |
| Projecting Sign (Ground Floor) | A | 16 sq. ft. | 1 per tenant w/ direct ground-floor access / Corner tenant, 1 per street frontage | X | 50% | Per Approved Signage Plan | |
| Projecting Sign (Above Ground Floor) | A | 16 sq. ft. | 1 per street frontage | X | 50% | Per Approved Signage Plan | |
| Provisional Fence Sign | A | Max. Hgt. 12 ft. | Not Eligible | ||||
| Wall Sign (Ground Floor) | A | 30 sq. ft. | 1 per tenant w/ direct ground-floor access | X | 50% | Per Approved Signage Plan | |
| Wall Sign (Above Ground Floor) | A | 1 sq. ft. per linear foot of building frontage | 1 per interior lot, 2 per corner lot | X | 50% | Per Approved Signage Plan | |
| Window Sign | A | No more than 25% of each window area | Ground floor and second floor only | X | 50% | Per Approved Signage Plan | |
| TOD-2 | |||||||
| A-Frame | A | 8 sq. ft. per side | Max. Hgt. 4 ft. | 1 per tenant w/ direct ground-floor access / Corner tenant, 1 per street frontage | Not Eligible | ||
| Attention-Getting Device | A | Not Eligible | |||||
| Awning or Canopy Sign & Open-Structural Framework Sign | A | 2 sq. ft. per linear foot of awning, canopy, or frame width | 1 per building | X | 50% | Per Approved Signage Plan | |
| Banner Sign (Freestanding) | A | 32 sq. ft. | Max. Hgt. 6 ft., except flags on single pole Max. Hgt. 25 ft. | 1 per lot | X | 50% | Per Approved Signage Plan |
| Banner Sign (Projecting) | A | 32 sq. ft. | 1 per street frontage | X | 50% | Per Approved Signage Plan | |
| Banner Sign (Wall Mounted) | A | 50 sq. ft. | Below parapet | 1 per lot | X | 50% | Per Approved Signage Plan |
| Billboard | ASSC Only | Requirements per § 17-406 | |||||
| Electronic Sign (Category I) | A | 15 sq. ft. | Per sign type used | 1 per lot | X | 50% | Per Approved Signage Plan |
| Electronic Sign (Category II) | A | 50 sq. ft. | Per sign type used | 2 per lot | X | 50% | Per Approved Signage Plan |
| Freestanding (Monument) | A | 32 sq. ft. | Max. Hgt. 6 ft. | X | 50% | Per Approved Signage Plan | |
| Painted / Mural Sign | A | 60 sq. ft. | 1 per lot | X | 50% | Per Approved Signage Plan | |
| Projecting Sign (Ground Floor) | A | 16 sq. ft. | 1 per tenant w/ direct ground-floor access / Corner tenant, 1 per street frontage | X | 50% | Per Approved Signage Plan | |
| Projecting Sign (Above Ground Floor) | A | 16 sq. ft. | 1 per street frontage | X | 50% | Per Approved Signage Plan | |
| Provisional Fence Sign | A | Max. Hgt. 12 ft. | Not Eligible | ||||
| Roof Sign | A | 2 sq. ft. per linear foot of building frontage | May not project any higher than 15 ft. above the roof | 1 per building | X | 50% | Per Approved Signage Plan |
| Wall Sign (Ground Floor) | A | 40 sq. ft. | 1 per tenant w/ direct ground-floor access | X | 50% | Per Approved Signage Plan | |
| Wall Sign (Above Ground Floor) | A | 1 sq. ft. per linear foot of building frontage | 1 per interior lot, 2 per corner lot | X | 50% | Per Approved Signage Plan | |
| Window Sign | A | No more than 40% of each window area | Ground floor and second floor only | X | 50% | Per Approved Signage Plan | |
| TOD-3 | |||||||
| A-Frame | A | 8 sq. ft. per side | Max. Hgt. 4 ft. | 1 per tenant w/ direct ground-floor access / Corner tenant, 1 per street frontage | Not Eligible | ||
| Attention-Getting Device | A | Not Eligible | |||||
| Awning or Canopy Sign & Open-Structural Framework Sign | A | 2 sq. ft. per linear foot of awning, canopy, or frame width | 1 per building | X | 50% | Per Approved Signage Plan | |
| Banner Sign (Freestanding) | A | 32 sq. ft. | Max. Hgt. 6 ft., except flags on single pole Max. Hgt. 25 ft. | 1 per lot | X | 50% | Per Approved Signage Plan |
| Banner Sign (Projecting) | A | 20 sq. ft. | 1 per street frontage | X | 50% | Per Approved Signage Plan | |
| Banner Sign (Wall Mounted) | A | 32 sq. ft. | Below parapet | 1 per lot | X | 50% | Per Approved Signage Plan |
| Billboard | ASSC Only | Requirements per § 17-406 | |||||
| Electronic Sign (Category I) | A | 15 sq. ft. | Per sign type used | 1 per lot | X | 50% | Per Approved Signage Plan |
| Freestanding (Monument) | A | 32 sq. ft. | Max. Hgt. 6 ft. | X | 50% | Per Approved Signage Plan | |
| Painted / Mural Sign | A | 40 sq. ft. | 1 per lot | X | 50% | Per Approved Signage Plan | |
| Projecting Sign (Ground Floor) | A | 16 sq. ft. | 1 per tenant w/ direct ground-floor access / Corner tenant, 1 per street frontage | X | 50% | Per Approved Signage Plan | |
| Projecting Sign (Above Ground Floor) | A | 16 sq. ft. | 1 per street frontage | X | 50% | Per Approved Signage Plan | |
| Provisional Fence Sign | A | Max. Hgt. 12 ft. | Not Eligible | ||||
| Wall Sign (Ground Floor) | A | 30 sq. ft. | 1 per tenant w/ direct ground-floor access | X | 50% | Per Approved Signage Plan | |
| Wall Sign (Above Ground Floor) | A | 1 sq. ft. per linear foot of building frontage | 1 per interior lot, 2 per corner lot | X | 50% | Per Approved Signage Plan | |
| Window Sign | A | No more than 25% of each window area | Ground floor and second floor only | X | 50% | Per Approved Signage Plan | |
| TOD-4 | |||||||
| A-Frame | A | 8 sq. ft. per side | Max. Hgt. 4 ft. | 1 per tenant w/ direct ground-floor access / Corner tenant, 1 per street frontage | Not Eligible | ||
| Attention Getting Device | A | Not Eligible | |||||
| Awning or Canopy Sign & Open-Structural Framework Sign | A | 2 sq. ft. per linear foot of awning, canopy, or frame width | 1 per building | X | 75% | Per Approved Signage Plan | |
| Banner Sign (Freestanding) | A | 32 sq. ft. | Max. Hgt. 6 ft., except flags on single pole Max. Hgt. 25 ft. | 1 per lot | X | 75% | Per Approved Signage Plan |
| Banner Sign (Projecting) | A | 32 sq. ft. | 1 per street frontage | X | 75% | Per Approved Signage Plan | |
| Banner Sign (Wall Mounted) | A | 50 sq. ft. | Below parapet | 1 per lot | X | 75% | Per Approved Signage Plan |
| Billboard | ASSC Only | Requirements per § 17-406 | |||||
| Electronic Sign (Category I) | A | 15 sq. ft. | Per sign type used | 1 per lot | X | 75% | Per Approved Signage Plan |
| Electronic Sign (Category II) | A | 50 sq. ft. | Per sign type used | 2 per lot | X | 75% | Per Approved Signage Plan |
| Electronic Sign (Category III) | ASSC Only | 750 sq. ft. | Per sign type used | X | 75% | Per Approved Signage Plan | |
| Freestanding (Monument) | A | 32 sq. ft. | Max. Hgt. 6 ft. | X | 75% | Per Approved Signage Plan | |
| Painted / Mural Sign | A | 60 sq. ft. | 1 per lot | X | 75% | Per Approved Signage Plan | |
| Projecting Sign (Ground Floor) | A | 16 sq. ft. | 1 per tenant w/ direct ground-floor access / Corner tenant, 1 per street frontage | X | 75% | Per Approved Signage Plan | |
| Projecting Sign (Above Ground Floor) | A | 16 sq. ft. | 1 per street frontage | X | 75% | Per Approved Signage Plan | |
| Provisional Fence Sign | A | Max. Hgt. 12 ft. | Not Eligible | ||||
| Roof Sign | A | 3 sq. ft. per linear foot of building frontage | May not project any higher than 20 ft. above the roof | 1 per building | X | 75% | Per Approved Signage Plan |
| Wall Sign (Ground Floor) | A | 40 sq. ft. | 1 per tenant w/ direct ground-floor access | X | 75% | Per Approved Signage Plan | |
| Wall Sign (Above Ground Floor) | A | 2 sq. ft. per linear foot of building frontage | 1 per interior lot, 2 per corner lot | X | 75% | Per Approved Signage Plan | |
| Window Sign | A | No more than 40% of each window area | Ground floor and second floor only | X | 75% | Per Approved Signage Plan | |
| OS | |||||||
| Attention-Getting Device | A | Not Eligible | |||||
| Awning or Canopy Sign & Open-Structural Framework Sign | A | 2 sq. ft. per linear foot of awning, canopy, or frame width | 1 per building | Not Eligible | |||
| Banner Sign (Freestanding) | A | 32 sq. ft. | 1 per building | Not Eligible | |||
| Banner Sign (Projecting) | A | 20 sq. ft. | 1 per building | Not Eligible | |||
| Banner Sign (Wall Mounted) | A | 32 sq. ft. | Below parapet | 1 per building | Not Eligible | ||
| Electronic Sign (Category I) | A | 15 sq. ft. | Per sign type used | 1 per lot | Not Eligible | ||
| Freestanding (Monument) | A | 32 sq. ft. | Max. Hgt. 6 ft. | Not Eligible | |||
| Freestanding (Pylon) | A | 50 sq. ft. | Minimum Hgt. 6 ft ./ Max. Sign Hgt. 20 ft. / Maximum Width 6 ft. | 3 per lot | Not Eligible | ||
| Painted / Mural Sign | A | 100 sq. ft. | 1 per building | Not Eligible | |||
| Projecting Sign (Above Ground Floor) | A | 12 sq. ft. | 1 per building | Not Eligible | |||
| Provisional Fence Sign | A | Max. Hgt. 12 ft. | Not Eligible | ||||
| Wall Sign (Ground Floor & Above Ground Floor) | A | 1 sq. ft. per linear foot of building frontage | 1 per building | Not Eligible | |||
| Window Sign | A | No more than 25% of each window area | Ground floor and second floor only | 2 per building | Not Eligible | ||
| PC-1 through PC-4 | |||||||
| A-Frame | A | 8 sq. ft. per side | Max. Hgt. 4 ft. | 1 per tenant w/ direct ground-floor access / Corner tenant, 1 per street frontage | Not Eligible | ||
| Attention-Getting Device | A | Not Eligible | |||||
| Awning or Canopy Sign & Open-Structural Framework Sign | A | 30 sq. ft. | 4 per building | X | 75% | Per Approved Signage Plan | |
| Banner Sign (Freestanding) | A | 32 sq. ft. | Max. Hgt. 6 ft., except flags on single pole Max. Hgt. 25 ft. | 1 per lot | X | 75% | Per Approved Signage Plan |
| Banner Sign (Projecting) | A | 32 sq. ft. | 1 per street frontage | X | 75% | Per Approved Signage Plan | |
| Banner Sign (Wall Mounted) | A | 120 sq. ft. | Below parapet | 1 per lot | X | 75% | Per Approved Signage Plan |
| Billboard | ASSC Only | Requirements per § 17-406 | |||||
| Electronic Sign (Category I) | A | 15 sq. ft. | Per sign type used | 1 per lot | X | 50% | Per Approved Signage Plan |
| Electronic Sign (Category II) | A | 50 sq. ft. | Per sign type used | 2 per lot | X | 50% | Per Approved Signage Plan |
| Electronic Sign (Category III) | ASSC Only | 750 sq. ft. | Per sign type used | X | 50% | Per Approved Signage Plan | |
| Electronic Sign (Category IV) | ASSC Only | 5,000sq. ft. | Per sign type used | X | 50% | Per Approved Signage Plan | |
| Electronic Sign (Category V) | ASSC Only | 10,500 sq. ft. | Per sign type used | X | 50% | Per Approved Signage Plan | |
| Freestanding (Monument) | A | 250 sq. ft. | Max. Hgt. 6 ft. | 1 per building | X | 75% | Per Approved Signage Plan |
| Freestanding (Pole) | A | 100 sq. ft. | Minimum Pole Hgt. 10 ft./ Max. Sign Hgt. 30 ft. | 1 per lot | X | 50% | Per Approved Signage Plan |
| Freestanding (Pylon) | A | 50 sq. ft. | Minimum Hgt. 6 ft. / Max. Sign Hgt. 20 ft./ Maximum Width 6 ft. | 1 per lot | X | 75% | Per Approved Signage Plan |
| Painted / Mural Sign | A | 100 sq. ft. | 1 per lot | X | 75% | Per Approved Signage Plan | |
| Projecting Sign (Ground Floor) | A | 20 sq. ft. | 1 per tenant w/ direct ground-floor access | X | 75% | Per Approved Signage Plan | |
| Projecting Sign (Above Ground Floor) | A | 250 sq. ft. | 1 per each street frontage of building | X | 75% | Per Approved Signage Plan | |
| Provisional Fence Sign | A | Max. Hgt. 12 ft. | Not Eligible | ||||
| Roof Sign | A | 4 sq. ft. per linear foot of building frontage | May not project any higher than 20 ft. above the roof | 1 per building | X | 75% | Per Approved Signage Plan |
| Wall Sign (Ground Floor) | A | 25 sq. ft. | 1 per tenant w/ direct ground-floor access / Corner tenant, 1 per street frontage | X | 75% | Per Approved Signage Plan | |
| Wall Sign (Above Ground Floor) | A | 6 sq. ft. per linear foot of building frontage | 2 per lot | X | 75% | Per Approved Signage Plan | |
| Window Sign | A | No more than 50% of each window area | Ground floor and second floor only | X | 75% | Per Approved Signage Plan | |
| * If, in the "Sign Types by Zoning District" section of this table, a sign type is not listed in a particular zoning district, then that sign type is prohibited in that zoning district. |
Reproduced from Table 17-201. Check it against the source before ordering.
Freestanding sign — maximum area
Table 17-201C-2: Freestanding Monument 32 sq. ft.; Freestanding Pole 16 sq. ft.
Set out in the same table as wall sign — maximum area above.
Freestanding sign — maximum height
Table 17-201C-2: Monument max. height 6 ft.; Pole min. pole height 10 ft., max. sign height 6 ft.
Set out in the same table as wall sign — maximum area above.
Projecting sign — maximum area
Table 17-201C-2: Projecting Sign (Ground Floor) 6 sq. ft.; Projecting Sign (Above Ground Floor) 12 sq. ft.
Set out in the same table as wall sign — maximum area above.
Window signs — maximum coverage
Table 17-201No more than 25% of each window area (C-2), ground floor and second floor only
Set out in the same table as wall sign — maximum area above.
Digital / electronic message centres
§ 17-407Electronic signs allowed by category (I=15 sq ft, II=50 sq ft, etc.). Text/digital graphics must be static or have min dwell time of 8 seconds; digital animation/videos max loop time of 1 minute. Category I message text static or depicted for at least 10 seconds. In C-2: Category I & II allowed by permit; Category III (300 sq ft) ASSC only.
“Text and digital graphics must be static or have a minimum dwell time of 8 seconds. Digital animation and videos must have a maximum loop time of 1 minute.”
Prohibited sign types
Table 17-201Any sign type not listed for a given zoning district is prohibited in that district.
“If, in the "Sign Types by Zoning District" section of this table, a sign type is not listed in a particular zoning district, then that sign type is prohibited in that zoning district.”
Which zoning district this describes
Table 17-201Requirements vary materially by zoning district. Figures reported are for C-2 (a general commercial district); other commercial districts (C-1, C-3, C-4, C-5 series) have different limits.
Set out in the same table as wall sign — maximum area above.
Not covered in the sign chapter we read: is a permit required?, wall sign — % of facade, freestanding sign — setback, projecting sign — clearance, illumination, temporary signs and banners. That doesn't mean the city has no rule — it may sit elsewhere in the code.
Spotted something wrong or out of date? Tell us — corrections from local sign shops are how this stays accurate.
Common questions
- How big can a wall sign be in Baltimore, MD?
- C-2: Ground floor wall sign 30 sq. ft. (1 per tenant w/ direct ground-floor access); Above ground floor 2 sq. ft. per linear foot of building frontage
- How big can a freestanding sign be in Baltimore, MD?
- C-2: Freestanding Monument 32 sq. ft.; Freestanding Pole 16 sq. ft.
- How tall can a freestanding sign be in Baltimore, MD?
- C-2: Monument max. height 6 ft.; Pole min. pole height 10 ft., max. sign height 6 ft.
- How big can a projecting sign be in Baltimore, MD?
- C-2: Projecting Sign (Ground Floor) 6 sq. ft.; Projecting Sign (Above Ground Floor) 12 sq. ft.
- How much of a window can be covered by signs in Baltimore, MD?
- No more than 25% of each window area (C-2), ground floor and second floor only
- Are digital or electronic message signs allowed in Baltimore, MD?
- Electronic signs allowed by category (I=15 sq ft, II=50 sq ft, etc.). Text/digital graphics must be static or have min dwell time of 8 seconds; digital animation/videos max loop time of 1 minute. Category I message text static or depicted for at least 10 seconds. In C-2: Category I & II allowed by permit; Category III (300 sq ft) ASSC only.
Tell me when Baltimore, MD changes its sign rules
We re-read the ordinance and compare it against our last reading. If a limit moves, you get one email quoting what changed. Most quarters, most cities change nothing — and we won't invent a reason to write.
One email per change, unsubscribe in one click, and we don't pass it on.
Quoting a sign job in Baltimore?
PrinterFlo prices signs by size and material, tracks the job from proof to install, and gets approvals signed off in one click.
See PrinterFlo